PARAMETERS

Permeate capacity 36–42 m³/h

Recovery 75 %

Maximum TDS 3000 mg/L

Influent flow demand (service) 50–60 m³/h

Operating pressure 8..12 bar

Power consumption 22 kW

PREKĖS ŽENKLAS:
8" MO36 RO System (EN), KAINA BE PVM: 86857.85124, KODAS: MO36TP5 | 001
MO36TP5

KEY FEATURES

  • Energy efficiency with Grundfos pump
  • Reliable performance with quality components and engineering
  • Individual project evaluation per request
  • ISO 9001 certified factory
  • CE marked and confirmed to be safe in accordance with EC New Approach Directives

SIZE AND WEIGHT

MO36

Dimensions, H×W×D: 2100 × 7000 × 2500 mm

Filter weight 1700 kg

SPECIFICATION

Equipment  

  • Grundfos® CR 45-4-2 high-pressure pump — 1 pc
  • 8040-6 membrane vessels — 6 pcs
  • Stainless steel housing with 7 PP 2,5 × 40″ filter — 2 pcs
  • Motorized feed water in, flush out butterfly valves — 2 pcs
  • Balancing concentrate reject, concentrate recycle valves — 2 pcs
  • Electrical cabinet with Ecosoft controller — 1 set
  • Piping, instrumentation — 1 set
  • Steel frame — 1 set  

Options

  • Filmtec™ XLE-440 / ECO PRO-440 or Ecosoft ELP-8040 membranes
  • Dosing pump for antiscalant or other RO chemicals
  • Permeate inlet for permeate membrane rinse
  • Raw water blending line

Сonnections

  • Influent water — DN100 (flange)
  • Permeate — DN80 (flange)
  • Concentrate — DN100 (flange)
  • CIP inlet — DN80 (flange)
  • CIP return — DN80 (flange)

Technical data

  • Permeate capacity¹ — 36 m³/h
  • Permeate recovery² — 75%
  • Maximum TDS — 3000 mg/L
  • Influent flow demand — 50…60 m³/h (service)
  • Operating pressure — 8…12 bar
  • Maximum pressure — 14 bar
  • Electrical requirements — 380...400 V, 50 Hz (3 ph)
  • Electrical power — 22 kW
  • Prefilter rating — 5 μm
    ¹ depends on feed water TDS, temperature, and permeate recovery
    ² for low scaling/fouling water

Feed water requirements

  • TDS — 3000 mg/L
  • hardness — 150 mg/L CaCO₃
  • iron — 0.1 mg/L
  • manganese — 0.05 mg/L
  • hydrogen sulfide — none
  • silicate — 20 mg/L
  • residual chlorine — 0.1 mg/L
  • SDI — 5
  • chemical oxygen demand - 4 mg/L O₂
MO36TP5